{"title":"GE Circuit Breaker Information","description":"\u003cdiv\u003e \u003cp\u003e\u003cspan\u003eBeck Electric Supply\u003c\/span\u003e has been a GE stocking distributor for 30 years. We \t  are confident that GE's attention to detail, product development, superior \t  service levels and quality distribution network is second to none. \u003c\/p\u003e \u003cp\u003e We have a wide range of GE Circuit Breakers in stock and ready to ship. \t  Please call our expert sales staff for your Molded Case breaker needs. \t  If we don't have it on the shelf we will be happy to place a factory \t  order and have your GE product in a few days.\u003c\/p\u003e \u003ch3\u003eQ-Line - Residential Circuit Breaker (THQB, THQC, THQL,THQP)\u003c\/h3\u003e \u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFeatures \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003e1\" or Ã‚ ½\" breaker \t    sizes available \u003c\/li\u003e \u003cli\u003eCopper to tabs copper connections with corrosion resisting \t    tin plated tabs \u003c\/li\u003e \u003cli\u003eEvery breaker exceeds UL, NEMA, ANSI, and CSA requirements\t\t    \u003c\/li\u003e \u003cli\u003e65oc\/75oc conductor rating \u003c\/li\u003e \u003cli\u003eQuick make \/ quick break box type terminals\t\t    \u003c\/li\u003e \u003cli\u003eHandle trips to center position, giving a clear indication of tripped \t    breaker Multi pole circuit breakers incorporate internal common trip\t\t    \u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTypes\u003cbr\u003e \u003c\/span\u003e\u003c\/strong\u003e15-50Amp, Ã‚ ½\", \t  THQP, 1 and 2 pole \u003cbr\u003e \t\t\t\t  15-125Amp, 1\", THQL, THHQL, TXQL, 1, 2 and 3 pole \u003cbr\u003e \t\t\t\t  125-200Amp, 1\", TQDL and THQDL, 2 and 3 pole\u003c\/p\u003e \u003ch3\u003eSpectra RMS Ã¢€\" Power Distribution \/ OEM \/ Electronic Trip\u003c\/h3\u003e \u003cp\u003e\u003cstrong\u003e\u003cspan\u003eFeatures\u003cbr\u003e \u003c\/span\u003e\u003c\/strong\u003eSpectra RMS Molded Case Circuit Breakers (SE150, SF250, SG600 and SK1200) \t  have digital, solid state, RMS sensing trip system with field installable \t  front mounted rating plugs to establish or change the breaker ampere \t  rating. Adjustable instantaneous with tracking short time is standard \t  on all frames including SE150. The trip system uses digital sampling \t  to determine the RMS value of sinusoidal and nonsinusoidal currents. \u003c\/p\u003e \u003cp\u003eMolded Case \t  \u003cbr\u003e \t\t\t\t  Solid State Trip System\u003c\/p\u003e \u003cul\u003e \u003cli\u003eAccurate Sensing\u003c\/li\u003e \u003cli\u003eAmbient Insensitive\u003c\/li\u003e \u003cli\u003eProvides Power Management Capabilities Options\u003c\/li\u003e \u003cli\u003eMicroVersaTrip Plus Trip \t    Unit\u003c\/li\u003e \u003cli\u003eMicroVersaTrip PM Trip Unit \u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eInterchangeable rating plugs for \t  easy de-rating without removing breaker Field installable accessories \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTypes\u003cbr\u003e \u003c\/span\u003e\u003c\/strong\u003eSE150 Current Limiting (SED, SEH, SEL, SEP) 15-32Amp, 2 and 3 pole \t  \u003cbr\u003e \t\t\t\t  SE150 Current Limiting (SED, SEH, SEL, SEP) 40-160Amp, 2 and 3 pole \t  \u003cbr\u003e \t\t\t\t  SF250 Current Limiting (SFH, SFL, SFP) 70-250Amp, 2 and 3 pole \u003cbr\u003e \t\t\t\t  SG600 \t  Current Limiting (SGH, SGL, SGP) 60-600Amp, 2 and 3 pole \u003cbr\u003e \t\t\t\t  SK1200 (SKH8, SKL8, \t  SKP8, SKH12, SKL12, SKP12) \u003cbr\u003e \t\t\t\t   \t  800Amp frame 300-800Amps\u003cbr\u003e \t\t\t\t   \t  1250Amp frame 600-1250Amps \u003c\/p\u003e \u003ch3\u003eMolded Case Circuit Breakers\u003c\/h3\u003e \u003cp\u003eGeneral Electric Molded Case Circuit Breakers \t  are being used to provide reliable circuit protection in switchboards, \t  motor control centers and lighting applications. Downtime is reduced \t  and fuse replacement is eliminated with circuit breakers. In case of \t  overload or short circuit, the breaker trips, opening the circuit and \t  protecting the conductors. When normal conditions are restored, the \t  breaker can be closed \"switched \t  on\" again.  \u003c\/p\u003e \u003cp\u003e \u003cspan\u003e\u003cstrong\u003eFeatures \u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e \t\t\t\t  Molded Case \u003cbr\u003e \t\t\t\t  Thermal Magnetic Trip \u003cbr\u003e \t\t\t\t  Proven Reliability \t  \u003cbr\u003e \t\t\t\t  Provide Cost Effective Solutions \u003cbr\u003e \t\t\t\t  Multiple types to fit in your application \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTypes \u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e \t\t\t\t  E150 Line (TEY, TEB, TED, THED) 10-150Amp, 1, 2 and 3 pole \u003cbr\u003e \t\t\t\t  F225 \t  Line (TFJ, TFK, THFK, TFL) 70-225Amp, 2 and 3 pole \u003cbr\u003e \t\t\t\t  J and K Frame Molded \t  Case Circuit Breakers\u003c\/p\u003e \u003cul\u003e \u003cli\u003eFeaturing Power + 4 Trip Units\u003c\/li\u003e \u003cli\u003e150-1200Amp, \t    120\/240 to 600Vac\u003c\/li\u003e \u003cli\u003eUL, CSA, NEMA ratings\u003c\/li\u003e \u003cli\u003e\"Push to Trip\" exercise \t    mechanism linkages\u003c\/li\u003e \u003cli\u003eCommon trip bar prevents single phasing\u003c\/li\u003e \u003cli\u003eHandle \t    indicates trip condition for rapid restoration of load\u003c\/li\u003e \u003cli\u003eTrip-Free \t    mechanism ensures complete circuit protection even if handle is held \t    in \"ON\" position\u003c\/li\u003e \u003cli\u003eFull line of internal and external accessories \t    for custom applications\u003c\/li\u003e \u003cli\u003eReverse feed standard\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eJ600 Line\u003c\/strong\u003e (TJJ, TJK THJK) \u003cbr\u003e \t\t\t\t     \t  400Amp frame 125 \t  to 400Amp \u003cbr\u003e \t\t\t\t     \t  600Amp frame 250 to 600Amp  \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eK1200 Line\u003c\/strong\u003e (TKM8, TKM12, THKM8, \t  THKM12) \u003cbr\u003e \t\t\t\t     \t  800Amp frame 300 to 800Amp \u003cbr\u003e \t\t\t\t     \t  1200 Amp frame 600 to 1200Amp  \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eR \t  Frame\u003c\/strong\u003e (TRL, TRP) \u003cbr\u003e \t\t\t\t     \t  400-1600Amp and 800-2000Amp  \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eCurrent Limiting Circuit \t  Breakers\u003c\/strong\u003e - 150, 225, 400 and 600Amp frames  \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eTri-Break\u003c\/strong\u003e (TB1, TB4, TB6, \t  TB8) \u003cbr\u003e \t\t\t\t     \t  15 to 800Amp, 3 pole  \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMag-Break\u003c\/strong\u003e (TEC, TEML, TECL, TFC, TBC4, TJC, \t  TBC6, TKC, TBC8) \u003cbr\u003e \t\t\t\t     \t  3-1200Amp, 2 and 3 pole \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003ePower Breaker II\u003c\/strong\u003e Ã¢€\" Insulated \t  Case Circuit Breakers \u003cbr\u003e \t\t\t\t  Power Break II Insulated Case Circuit Breakers \t  are highly compact, heavy duty breakers that combine ease of use, aesthetics \t  and state of the art performance in 200Amp through 4000Amp frame sizes, \t  rated for up to 200,000 Amps RMS symmetrical for 240Vac, in drawout \t  and stationary versions  \u003c\/p\u003e \u003cp\u003e\u003cstrong\u003ePower Breaker I\u003c\/strong\u003e Ã¢€\" Insulated Case Circuit Breakers \t  \u003cbr\u003e \t\t\t\t  The GE line of Power Break Insulated Case Circuit Breakers offers the \t  rugged, reliable type of system protection critical for heavy duty \t  applications. Power Break circuit breakers are rated up to 200,000 \t  Amp RMS symmetrical interrupting capacity without fuses or current \t  limiters. The Power Break design consists of five physical envelope \t  sizes, providing protection from 100Amp to 4000Amps. Available in drawout \t  or stationary versions.\u003c\/p\u003e\n\u003c\/div\u003e","products":[],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0877\/4238\/2384\/collections\/Circuit_Breakers_9ed781c1-2506-44b6-a0e3-39b05fea4e0f.jpg?v=1777953544","url":"https:\/\/beckelectric.com\/collections\/circuit-breakers-general-electric-ge-circuit-breaker-information.oembed","provider":"Beck Electric Supply","version":"1.0","type":"link"}